Tavlit Semi-Automatic filter fibreglass-reinforced nylon 2" male thread 10bar 120micron disc type Adir One-Action Super
Product information
One Action cleaning saves water as the water used for flushing the discs is filtered with an internal screen and put back in the system.
Comes with a standard pressure indicator that shows the user that the filter is dirty and needs flushing (preset value set to 0.5b).
Flushing is performed simply by turning the operation handle ¼ of a turn for 20 seconds.
During flushing, the flow to the field is uninterrupted.
Minimum flushing pressure required: 2bar.
Flushing flow rate: 2bar = 9.3m3/h, 3bar = 12m3/h.
When the filter is clean after flushing, the user needs to flush the secondary port by opening the service valve for 10 seconds.
We recommend to install a manual valve (open/close) in the upstream.
Connection | male thread |
---|---|
Filter area | 1.025 m² |
Filtration | 120 micron |
Material | fibreglass-reinforced nylon |
Material filter element | disc |
Material seal | EPDM |
Pressure | 10 bar |